5212
SCREED 20MPa

Reliable solution for residential building

Indoor and outdoor cement screed for light load surfaces

  • Reliable solution: Underlay for low-load paved surfaces. For indoors and outdoors
  • Machinable: for quick and efficient work
  • Earth moist consistency: no excess water, so dries out faster
  • Creates a perfect, flat and strong surface

Area of application

  • Outdoor: floor
  • Indoor: floor

Heating and cooling area

  • Floor

Processing method

  • For hand and machine processing
  • For indoor and outdoor use. Can be used as a floating screed to prepare the subfloor for the installation of floor coverings or as a contact screed in direct contact with the subfloor. Also suitable for underfloor heating.

Processing details

Learn more about technical details for processing this product.

Substrate requirement

The substrate must comply with the applicable standards, must be solid, free of loose particles, free of dust, paint, residues of demoulding substances and efflorescence. It must be sufficiently rough, dry and evenly absorbent. The surface shall not be frozen or water-repellent. The substrate must be stable in volume.

Substrate preparation

To produce a contact screed, the low strength layer formed on the surface of cementitious screeds must be removed using a mechanical device (shot-blasting machine). We then recommend applying Cemix bonding bridge to the substrate with a hard fibre plastic broom in order to achieve perfect adhesion. The cement screed is applied while the bonding bridge is still wet.
Pay attention to construction and construction joints to allow vertical building elements (walls, pillars, pipes, etc.) to expand.
The substrate must comply with the applicable regulations, standards or recommendations of the material manufacturer.
To produce a floating or sliding screed, the separating layer must be laid over the entire surface before the cement screed is applied. If the screed is laid on a heat-insulating layer (floating screed), a separating layer is always applied between the heat-insulating material and the screed. An expansion strip of at least 5 mm must be applied along the vertical walls and around the through pipe, at least 8 mm in the case of underfloor heating and at least 10 mm in outdoor areas. Adjacent surfaces that are larger than 20 m2 must be separated with an expansion profile.

Preparation of the mixture

Pour 25 KG of CEMIX SCREED 20MPa into 2,2 L of clean water. Mix 5 minutes thoroughly using a concrete mixer, horizontal mixer (e.g., PFT HM24), or by hand to a homogeneous, lump-free mixture. Special screed mixing and conveying equipment can also be used to apply the wet screed.
Apply using standard screeding techniques. Ensure the mixture is evenly spread and compacted for optimal performance.
Do not add foreign materials.
For more information, refer to product documents on Cemix's website.

Water demand

CEMIX_blue_handling_water-quantity_25kg_2,2l CEMIX_blue_handling_water-quantity_40kg_3,5l
Quantity Liters (recommended)
25 kg 2,2 L
40 kg 3,5 L

Mixing

CEMIX_blue_handling_swirl_5min
Mixing time
5 min

Processing instructions

Spread the mass on the prepared substrate and compact it, e.g. with the strokes of a trowel. Then flatten the surface with aluminium H profile lat and smooth it with a plastic or steel trowel. An advantage is the possibility of pulling down with a vibrating lat.

Application thickness

CEMIX_blue_techdata_80_30mm
Minimum layer thickness 30 mm
Maximum layer thickness 80 mm

Consumption

CEMIX_blue_techdata_trowel_2,0kg-1mm
Material consumption min.
2
Material consumption max.
-
Material consumption in measuring unit
kg/m²/mm

Working time (potlife)

CEMIX_blue_handling_trowel_120min

2 h

Walkability after

CEMIX_blue_handling_trespass_24h

1 d

Treatment after application

Avoid the negative effects of sun, heat and draughts. Protect from frost and rain. Direct heating of the surface is prohibited. Keep the screed in a moist condition for 2-3 days.

Technical parameters

Main binder Grey cement
Flammability class A1fl
Max. grain size 4mm
Full load after 178 h
Compressive strength 28 days in N/mm² 20 N/mm²
Flexural strength 28 days in N/mm² 3.5 N/mm²