8211
TILE ADHESIVE PRO
Increased strength.
For medium size porcelaine stoneware and all ceramic tiles.
- C2: Adhesive strengths > 1MPa. For -15 - +70°C. Carries heavy tiles of mid and large size on walls.
- For all dry and wet indoor areas. For outdoor areas protected from sun and moisture. Frost resistant.
- For heated floors and walls.
- (E) Extented open time: For tiling of large areas in one step.
- T: Reduced slip. For tiling from top to floor.
- 3-12mm: For large applciation thickness.
- For ceramics with low water absorption.
- Drivable: For garages with traffic loads up to 3,5to.
Area of application
- Outdoor: floor + wall
- Indoor: floor + wall
- For humid areas
Heating and cooling area
- Floor + Wall
Processing method
- For hand processing
- Suitable for ceramic non-absorbent mosaic tiles.
- For floors and walls in all dry and wet indoor areas. Also suitable for sun-protected outdoor areas.
- Suitable for areas with traffic loads up to 3,5to: car, forklift.
Price list
Code
Packaging
Code
Packaging
25 kg
Processing details
Learn more about technical details for processing this product.
Substrate requirement
The substrate must comply with the applicable standards, must be solid, free of loose particles, free of dust, paint, residues of demoulding agents and efflorescence. It must be sufficiently rough, dry and evenly absorbent. The surface shall not be frozen or water-repellent. The substrate shall be stable in volume and have required flatness.
Substrate preparation
The substrate must be clean, dry and load-bearing and not frozen. Treat absorbent substrates with Cemix primer. Roughen smooth or non-absorbent substrates or use Cemix Contact Bridge. The substrate must comply with the applicable norms, standards or recommendations of the material manufacturer.
Preparation of the mixture
Pour 25KG of CEMIX 8211 TILE ADHESIVE PRO into 8,25-8,75 L of clean water. Mix for 5 minutes with a slow-speed paddle mixer to a homogeneous mixture without lumps. Leave to rest for 3 minutes. Then mix again briefly.
Water demand

Quantity | Liters (Min) | Liters (Max) |
---|---|---|
1 kg | 0,33 l | 0,35 l |
25 kg | 8,25 l | 8,75 l |
Mixing


Processing instructions
First, apply a thin layer of the adhesive to the substrate with the straight edge of the stainless steel trowel. Then, apply sufficient adhesive for the appropriate layer with the notched side of the trowel, if possible in one direction.
Lay the tiles and adjust them within the open time period.
In case the open time is exceeded, do not tile anymore. The applied adhesive must be removed in this case.
In case of uneven substrates use buttering floating process : Apply adhesive as described also on the reverse side of the tile.
Clean the tile from fresh adhesive with a sponge trowel and clean water.
Application thickness

Minimum layer thickness | 3 mm |
---|---|
Recommended layer thickness | 6 mm |
Maximum layer thickness | 12 mm |
Consumption

Open time according to EN12004

>30 min
Working time (potlife)

180 min
Walkability after

48 h
Treatment after application
Non-absorbent tiles prolong the curing period.
Avoid sun, heat, humidity and draughts. Protect from frost. Direct heating of the surface is not permitted.
Tool and cleaning instructions
After finishing work, wash the tools immediately with clean water. Remove dried residues mechanically.
Smaller deposits can be removed with acetic (diluted acetic acid) or a special cement paint cleaner.
Technical parameters
Main binder | Grey cement |
Flammability class | A1 |
Max. grain size | 0,7mm |
Full load after | 7 d |
Adhesive tensile strength after water storage in >N/mm²(EN12004) | 1 |
Adhesive tensile strength after warm storage in >N/mm² (EN12004) | 1 |
Adhesion tensile strength after freeze thaw storage in >N/mm² | 1 |
Adhesive tensile strength after dry storage in >N/mm² (EN12004) | 1 |
Setting time and tensile adhesion after 30 min | 0.5 |
Vertical slip (EN12004) | 0.5 mm |
Density in Kg/m³ | 1250 |
Files
|